Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. Fac. Odontol. (B.Aires) ; 37(85): 59-66, 2022. ilus
Article in Spanish | LILACS | ID: biblio-1411262

ABSTRACT

En este artículo se desarrolla el consenso alcanzado entre profesores, referido a los conceptos generales, componentes y la secuencia del diseño de la prótesis parcial removible, durante la formación del odontó-logo en el ámbito de la Facultad de Odontología de la Universidad de Buenos Aires (AU)


This article develops the consensus between professors on the general concepts, components, and the sequence of the design of the partial removable prosthesis during the training of the dentist in the field of the Faculty of Dentistry of the University of Buenos Aires (AU)


Subject(s)
Dental Prosthesis Design/methods , Consensus , Denture, Partial, Removable , Schools, Dental , Students, Dental , Dental Prosthesis Retention/methods , Dental Occlusion , Dental Stress Analysis , Education, Predental/methods , Faculty, Dental
2.
Rev. Fac. Odontol. (B.Aires) ; 37(86): 1-12, 2022. ilus, tab
Article in Spanish | LILACS | ID: biblio-1413026

ABSTRACT

El objetivo de este estudio fue evaluar con microto-mografía los poros existentes entre el cemento de resina, poste de fibra y paredes del conducto en los distintos tercios radiculares en premolares inferio-res. Se utilizaron 15 premolares inferiores unirra-diculares humanos recientemente extraídos. Se les realizó el tratamiento endodóntico, y se obturó con conos de gutapercha y cemento endodóntico a base de resina. Una vez desobturados se procedió a la ce-mentación de los postes. Cada muestra se posicionó en un accesorio personalizado y se escaneó utilizan-do un Microtomógrafo. Con el software CTAn v.1.12 (Bruker-microCT) se analizaron las microtomografías para obtener el volumen de interés (VOI) que permi-tió calcular el área de superficie (mm2) y volumen de cada poro (mm3) entre la dentina y el poste a nivel co-ronal, medio y apical. Los datos fueron analizados me-diante las pruebas estadísticas de Friedman o ANOVA de medidas repetidas. El volumen de los poros entre los tres tercios radiculares mediante la prueba de Friedman, encontró una diferencia global significativa (F = 30,00; p < 0,05). El tercio en donde los poros presentaron un mayor volumen (mm3) fue el tercio coronal (mediana: 0,29250), seguido por los tercios medio (mediana: 0,03200), y apical (mediana: 0,00140). La comparación de la superficie de los poros entre los 3 tercios brindó un resultado análogo al de la comparación del volumen. La mayor superficie (mm2) correspondió al tercio coronal (media ± DE = 1,66377 ± 0,27175), seguido por los tercios medio (media ± DE = 1,16210 ± 0,20343) y apical (media ± DE = 0,41074 ± 0,12641). La microtomografía permitió realizar un análisis cuantitativo y cualitativo de los poros en toda la muestra, sin deterioro de la misma. Se puede concluir que el tercio coronal presenta más poros que el tercio apical con la técnica de cementación utilizada. En cuanto a la superficie y volumen de los poros, los resultados encontrados son similares a los reporta-dos por diversos autores (AU)


The aim of this study was to evaluate with microtomography the existing pores between the resin cement, fiber post and canal walls in the different in thirds of the canal, in single-root lower premolars. Fifteen recently extracted human single root lower premolars were used, endodontically treated, and filled with gutta-percha cones and resin-based endodontic cement. Once unfilled, the posts were cemented. Each sample was positioned on a custom fixture and scanned using a Microtomograph. Each sample was evaluated using CTAn v.1.12 software (Bruker-microCT) to obtain the surface area (mm2), volume of interest (mm3) of each pore between dentin and post at the coronal, middle and apical levels. Data were analyzed using Friedman's tests or repeated measures ANOVA. The volume of the pores between the three root thirds using the Friedman test, a significant global difference was found (F = 30.00; p < 0.05). The third in which the pores presented a greater volume (mm3) was the coronal third (means: 0.29250), followed by the middle (means: 0.03200) and apical (means: 0.00140) thirds. The comparison of the pore surface between the 3 thirds gave an analogous result to that of the volume comparison. The largest surface area (mm2) corresponded to the coronal third (mean ± SD 1.66377 ± 0.27175), followed by the middle (mean ± 1.16210 ± 0.20343) and apical (mean ± 0.41074 ± 0.12641) thirds.Microtomography allowed a quantitative and qualitative analysis of the pores in the entire sample without deterioration. It can be concluded that the coronal third has more pores than the apical third with the cementation technique used. Regarding the surface and volume of the pores, the results found are similar to those reported by various authors (AU)


Subject(s)
Porosity , Post and Core Technique , Cementation/instrumentation , X-Ray Microtomography , Bicuspid , Analysis of Variance , Resin Cements , Imaging, Three-Dimensional/methods , Fibric Acids
3.
Acta odontol. latinoam ; 30(1): 33-38, 2017. ilus, tab, graf
Article in English | LILACS | ID: biblio-907405

ABSTRACT

The aim of this study was to analyze in vitro temperature changeson the outer surface of the dental root during mechanical fillingremoval procedures.Thirty recently extracted single­rooted lower premolars were cuttransversally at 16 mm from the apex in order to standardizesample length. Endodontic treatment was performed on them. Thefilling material was subsequently removed using Gates Glidden(G1, G2, G3); Peeso (P1, P2, P3) and PostecPlus FRC (FRC)reamers while temperatures were measured on the outer surfaceusing a digital device with thermocouple at 0, 2, 4, 6, 8, 10 and 15seconds. Temperatures were compared using repeated measuresANOVA followed by pairwise comparison with Tukey’s test.All reamers caused significant temperature variation betweendifferent times (p<0.05). Pairwise comparisons indicated thattemperature increased with time for all reamers (p<0.05).Significant differences in temperature were found betweendifferent reamers after 0, 2, 4, 6, 8, 10 and 15 seconds (p<0.05)...


El objetivo del presente trabajo fue estudiar los cambios térmicosin vitro en la superficie externa de la raíz del diente, generadosdurante los procedimientos de desobturación mecánica.Se utilizaron 30 premolares inferiores unirradiculares reciente ­mente extraídos, que fueron seccionados transversalmente a16 mm del ápice para estandardizar la longitud de lasmuestras. Se realizó luego su tratamiento endodóntico. Lasmediciones de temperatura fueron realizadas mediante undispositivo digital con termocupla, en la superficie externa adiferentes tiempos (t = 0, 2, 4, 6, 8, 10 y 15 segundos), durantela desobturación con fresas de Gates Glidden (G1, G2, G3);de Peeso (P1, P2, P3) y la correspondiente a PostecPlus FRC(FRC). Los registros de temperatura fueron comparadosmediante pruebas de ANOVA de medidas repetidas, seguidaspor comparaciones entre pares mediante la prueba de Tukey.Con todas las fresas se encontró una variación significativa dela temperatura entre los diferentes tiempos (p<0.05). Las compa ­raciones entre pares indicaron que la temperatura se incrementócon el tiempo en todas las fresas (p<0.05). Se detectarondiferencias significativas de temperatura entre diferentes fresasdespués de 0, 2, 4, 6, 8, 10 y 15 segundos (p<0.05)...


Subject(s)
Humans , Dental Instruments , Root Canal Preparation/instrumentation , Transition Temperature , Tooth Root/physiology , Analysis of Variance , Calorimetry/methods , In Vitro Techniques , Data Interpretation, Statistical
SELECTION OF CITATIONS
SEARCH DETAIL